Free generator · Runs in your browser

Square-to-round adapter generator Any shape to any shape.

Make duct transitions from square, rectangle, slot, oval or fan to round: offset, tilted or twisted, with flanges, push-fit cuffs and grip ribs. Or morph a star into a circle for a pot or vase.

  • Private by designNothing leaves this device
  • Seven end shapesFans from 25 to 140 mm
  • Airflow shownOpen area at every point
  • Ready to sliceSTL and 3MF files

Drag to rotate · Scroll or pinch to zoom · Arrow keys when focused

Size
—
Filament
—
Parts
—
Fits
—

Start from

Make

Make

A solid body: slice it in spiral vase mode for a single wall. For a duct, set bottom layers to 0 so it is open at both ends.

2.0 mm
0.30 mm

Used by ends that go over a port or into a hose: added or taken off on every side.

End A (bottom)

End A sits on the bed.

The duct opens to a circle as wide as the fan frame allows, and a square plate takes the fan’s four screws.

Polygons and stars: across the corners.

6.0 mm

Corners never go below what keeps the wall even.

6
0.60

How far in the star’s inner corners sit, as a share of its diameter.

Over a port: the end’s inside is your size plus the clearance. Into a hose: its outside is your size minus the clearance.

2.4 mm

Two or three nozzle widths prints strong walls.

1.0 °

The tip is looser and the fit tightens as you push it on.

3
1.0 mm
6.0 mm

For a foam strip or an O-ring: measure its thickness.

1.2 mm
15 mm

4.5 mm suits M4 screws.

Automatic: a rectangle for square, slot and oval ends, a bolt circle for the rest.

4.0 mm
3.0 mm
12 mm

How far the end runs straight before the shape starts to change.

End B (top)

End B is at the top, or at the side when tilted.

The duct opens to a circle as wide as the fan frame allows, and a square plate takes the fan’s four screws.

Polygons and stars: across the corners.

6.0 mm

Corners never go below what keeps the wall even.

6
0.60

How far in the star’s inner corners sit, as a share of its diameter.

Over a port: the end’s inside is your size plus the clearance. Into a hose: its outside is your size minus the clearance.

2.4 mm

Two or three nozzle widths prints strong walls.

1.0 °

The tip is looser and the fit tightens as you push it on.

3
1.0 mm
6.0 mm

For a foam strip or an O-ring: measure its thickness.

1.2 mm
15 mm

4.5 mm suits M4 screws.

Automatic: a rectangle for square, slot and oval ends, a bolt circle for the rest.

4.0 mm
3.0 mm
40 mm

How far the end runs straight before the shape starts to change.

Path

From end A’s face to the centre of end B. With a straight duct it is the whole length.

0 °

Turns end B towards +x: 90° makes an elbow or a floor vent boot. Pots tilt up to 30°.

0 °

Turns end B’s shape about its own centre.

Path
Shape change

Print

Cut across: two pieces that each print standing up and push together. Lengthwise halves: for ducts too tall for your printer.

10 mm
0.20 mm
3.4 mm

3.4 mm takes M3 screws or 3 mm pins.

Short pins to line the halves up for gluing.

Download

Building the preview…

Print it well

    Everything is built on this device. Nothing you type or upload is sent anywhere.

    Advertisement

    The method

    How to make a square-to-round adapter

    Pick a shape for each end, enter the size you measured, and say whether the end goes over a port, into a hose, or is the duct’s own inside or outside. The generator traces both outlines, gives them the same number of points spaced evenly along each edge, lines them up so the duct doesn’t twist, and blends one into the other along the path you set.

    1. End A sits on the bed. Give it a flange or a fan plate if it screws on.
    2. End B is at the top. Choose a tapered cuff or grip ribs for a hose.
    3. Path: the height, a sideways offset, a tilt for elbows and boots, and a twist.
    4. Check the readout: the open area and the steepest overhang.
    5. Download and print end A down.

    Shapes

    Shapes, fits and what the size means

    You chooseThe size you enterWhat gets built
    Slides over a portThe port’s outsideThe end’s inside is that plus the clearance on every side
    Goes into a hoseThe hose’s insideThe end’s outside is that minus the clearance
    Inside sizeThe opening you wantThe inside is exactly that, the wall grows outward
    Outside sizeThe outside you wantThe outside is exactly that, the wall grows inward
    Polygon or starAcross the cornersThe corners are rounded at least enough to keep the wall even
    FanThe fan sizeA round opening as wide as the frame allows, on a square plate

    The wall is exactly the thickness you set at both ends. In between, the two surfaces blend together, so a steep change can make it a little thinner when measured square to the wall.

    Fans

    Fan sizes and screw holes

    FanHole spacingPlate holeDuct opening (2.4 mm wall)
    25 mm20 mm2.9 mm (M2.5)18 mm
    30 mm24 mm3.4 mm (M3)23 mm
    40 mm32 mm3.4 mm (M3)33 mm
    50 mm40 mm4.5 mm (M4)43 mm
    60 mm50 mm4.5 mm (M4)53 mm
    70 mm61.5 mm4.5 mm (M4)63 mm
    80 mm71.5 mm4.5 mm (M4)73 mm
    92 mm82.5 mm4.5 mm (M4)85 mm
    120 mm105 mm4.5 mm (M4)113 mm
    140 mm124.5 mm4.5 mm (M4)133 mm

    Hole spacing is centre to centre on one side, from published fan drawings (see Sources). Makers differ a little, so measure your fan if the holes must line up exactly. To join two fan sizes with a flat plate or a short duct, the fan grill generator has an adapter mode.

    Airflow

    Open area and airflow

    The readout shows the open area inside each end and at the narrowest point of the duct. If the narrowest point is smaller than the smaller end, the duct restricts the flow, and the readout gives that as a percentage. For dust collection keep it close to zero: a lengthened, gentler transition usually fixes it.

    A 100 mm circle has an open area of about 7,850 mm². A 100 mm square with 6 mm corners has about 9,970 mm².

    Clothes dryers: building codes (for example section 1502.4.1 of the residential code, as adopted in Ohio) call for a smooth metal exhaust duct of 4 inches (102 mm). Don’t use a printed plastic duct on a clothes dryer.

    Printing

    Printing tips

    • End A down, as laid out. Flanges and fan plates on end A print flat on the bed.
    • Overhangs: most printers handle walls up to about 45° from vertical without supports. The readout gives the steepest wall; above 45°, lengthen the duct, reduce the offset, or cut it across into two pieces.
    • Elbows and boots: “Two pieces, cut across” makes each piece a gentler bend that stands on its own cut. The spigot pushes into the socket; glue it with a little CA or epoxy.
    • Lengthwise halves lie on their cut faces, so the inside of each half is an arch: turn on supports. Line them up with pins or M3 screws through the lugs and glue the seam.
    • Vase mode: for a single smooth wall, choose “Solid for vase mode” and turn on spiral vase in your slicer.
    • Material: PETG or ASA for warm air and outdoor vents. PLA softens at about 60 °C.

    Questions, answered

    Is it free to use?

    Yes. No account, no watermark, no limits.

    Will it fit my printer?

    Choose your printer below the preview to check. A duct too tall for your printer can be cut across into two pieces or split into two halves.

    How do I join two round hoses of different sizes?

    Use the hose adapter generator: it makes round reducers, elbows, Y-splitters, barbs and caps.

    Is it airtight?

    Printed walls can leak a little air. Three or more perimeters, or a gasket groove with foam tape at each joint, help. Seal joints with foil tape for ventilation.

    Can I sell what I print?

    The designs you make are yours. We make no safety or code compliance claims, so test anything you sell and don’t promise more than you have tested.

    Sources

    Print advice is a starting point drawn from these references, checked on 2026-11-13. Community posts are one maker's experience, not a specification.

    1. Computer fan: fan sizes and screw hole spacing Wikipedia
    2. AFB1212HHE-F00 specification for approval (120 mm fan) Delta Electronics
    3. AFB 80 × 80 × 25.4 mm series datasheet Delta Electronics
    4. IS 1821:1987 Dimensions for clearance holes for bolts and screws (identical with ISO 273) Bureau of Indian Standards
    5. Ohio Admin. Code 4101:8-15-01, Exhaust systems (residential code section 1502.4.1, dryer duct material and size) Legal Information Institute, Cornell Law School
    6. The ultimate guide to the 45-degree rule in 3D printing Snapmaker
    7. Layers and perimeters (spiral vase) Prusa Knowledge Base