The method
How to make a square-to-round adapter
Pick a shape for each end, enter the size you measured, and say whether the end goes over a port, into a hose, or is the duct’s own inside or outside. The generator traces both outlines, gives them the same number of points spaced evenly along each edge, lines them up so the duct doesn’t twist, and blends one into the other along the path you set.
- End A sits on the bed. Give it a flange or a fan plate if it screws on.
- End B is at the top. Choose a tapered cuff or grip ribs for a hose.
- Path: the height, a sideways offset, a tilt for elbows and boots, and a twist.
- Check the readout: the open area and the steepest overhang.
- Download and print end A down.
Shapes
Shapes, fits and what the size means
| You choose | The size you enter | What gets built |
|---|---|---|
| Slides over a port | The port’s outside | The end’s inside is that plus the clearance on every side |
| Goes into a hose | The hose’s inside | The end’s outside is that minus the clearance |
| Inside size | The opening you want | The inside is exactly that, the wall grows outward |
| Outside size | The outside you want | The outside is exactly that, the wall grows inward |
| Polygon or star | Across the corners | The corners are rounded at least enough to keep the wall even |
| Fan | The fan size | A round opening as wide as the frame allows, on a square plate |
The wall is exactly the thickness you set at both ends. In between, the two surfaces blend together, so a steep change can make it a little thinner when measured square to the wall.
Fans
Fan sizes and screw holes
| Fan | Hole spacing | Plate hole | Duct opening (2.4 mm wall) |
|---|---|---|---|
| 25 mm | 20 mm | 2.9 mm (M2.5) | 18 mm |
| 30 mm | 24 mm | 3.4 mm (M3) | 23 mm |
| 40 mm | 32 mm | 3.4 mm (M3) | 33 mm |
| 50 mm | 40 mm | 4.5 mm (M4) | 43 mm |
| 60 mm | 50 mm | 4.5 mm (M4) | 53 mm |
| 70 mm | 61.5 mm | 4.5 mm (M4) | 63 mm |
| 80 mm | 71.5 mm | 4.5 mm (M4) | 73 mm |
| 92 mm | 82.5 mm | 4.5 mm (M4) | 85 mm |
| 120 mm | 105 mm | 4.5 mm (M4) | 113 mm |
| 140 mm | 124.5 mm | 4.5 mm (M4) | 133 mm |
Hole spacing is centre to centre on one side, from published fan drawings (see Sources). Makers differ a little, so measure your fan if the holes must line up exactly. To join two fan sizes with a flat plate or a short duct, the fan grill generator has an adapter mode.
Airflow
Open area and airflow
The readout shows the open area inside each end and at the narrowest point of the duct. If the narrowest point is smaller than the smaller end, the duct restricts the flow, and the readout gives that as a percentage. For dust collection keep it close to zero: a lengthened, gentler transition usually fixes it.
A 100 mm circle has an open area of about 7,850 mm². A 100 mm square with 6 mm corners has about 9,970 mm².
Clothes dryers: building codes (for example section 1502.4.1 of the residential code, as adopted in Ohio) call for a smooth metal exhaust duct of 4 inches (102 mm). Don’t use a printed plastic duct on a clothes dryer.
Printing
Printing tips
- End A down, as laid out. Flanges and fan plates on end A print flat on the bed.
- Overhangs: most printers handle walls up to about 45° from vertical without supports. The readout gives the steepest wall; above 45°, lengthen the duct, reduce the offset, or cut it across into two pieces.
- Elbows and boots: “Two pieces, cut across” makes each piece a gentler bend that stands on its own cut. The spigot pushes into the socket; glue it with a little CA or epoxy.
- Lengthwise halves lie on their cut faces, so the inside of each half is an arch: turn on supports. Line them up with pins or M3 screws through the lugs and glue the seam.
- Vase mode: for a single smooth wall, choose “Solid for vase mode” and turn on spiral vase in your slicer.
- Material: PETG or ASA for warm air and outdoor vents. PLA softens at about 60 °C.
Questions, answered
Is it free to use?
Yes. No account, no watermark, no limits.
Will it fit my printer?
Choose your printer below the preview to check. A duct too tall for your printer can be cut across into two pieces or split into two halves.
How do I join two round hoses of different sizes?
Use the hose adapter generator: it makes round reducers, elbows, Y-splitters, barbs and caps.
Is it airtight?
Printed walls can leak a little air. Three or more perimeters, or a gasket groove with foam tape at each joint, help. Seal joints with foil tape for ventilation.
Can I sell what I print?
The designs you make are yours. We make no safety or code compliance claims, so test anything you sell and don’t promise more than you have tested.
Sources
Print advice is a starting point drawn from these references, checked on 2026-11-13. Community posts are one maker's experience, not a specification.
- Computer fan: fan sizes and screw hole spacing Wikipedia
- AFB1212HHE-F00 specification for approval (120 mm fan) Delta Electronics
- AFB 80 × 80 × 25.4 mm series datasheet Delta Electronics
- IS 1821:1987 Dimensions for clearance holes for bolts and screws (identical with ISO 273) Bureau of Indian Standards
- Ohio Admin. Code 4101:8-15-01, Exhaust systems (residential code section 1502.4.1, dryer duct material and size) Legal Information Institute, Cornell Law School
- The ultimate guide to the 45-degree rule in 3D printing Snapmaker
- Layers and perimeters (spiral vase) Prusa Knowledge Base