Volumetric photopolymerizationManufacturer image: Readily3DReadily3D Tomolite
Light fields from multiple directions form structures within a volume of photosensitive material.
Source reviews: 2026-10-16.
Specifications are reported claims, not independent test results.
The details that matter.
Published specifications for this model. Follow a field's source for its configuration and measurement conditions; older fields refer to the profile's reference list.
| Introduction year | Not verified |
|---|---|
| Model family | Not verified |
| Process | Volumetric photopolymerization |
| Build envelope (X × Y × Z) | Not verified |
| Nominal box volume | Not verified |
| Enclosure | Not verified |
| Materials cited in this profile | Photosensitive bioinks |
| Manufacturer listing status | Manufacturer documentation verified; availability not established |
| Regional stock and price | Check the manufacturer |
| Market grouping | Professional · editorial grouping |
Technical specifications
| Pixel Size (µm) | 14 Projection pixel size before the stated magnification; not printed-part resolution. |
|---|---|
| Pre Vial Magnification | 2 |
| Standard Build Diameter (mm) | 6.3 |
| Performance Build Diameter (mm) | 12.5 |
| Minimum Stated Build Height (mm) | 25 Source states height ≥25 mm; this is a lower bound, not a maximum. |
| Indicative Print Time (s) | 30–120 Source explicitly says material dependent. |
| Irradiance Range | 1–20 mW/cm², average at container |
| Standard Wavelength | 405 ±5 nm |
| Performance Wavelength | 400 ±1 nm |
| Machine dimensions (mm) | 270 × 300 × 670 |
| Container | Sealed, reusable autoclavable glass vial |
| Software | Apparite |
| File Formats | STL |
| Material Classes | Hydrogels, Acrylics, Silicones |
Pixel size, pre-vial magnification and optical-dose resolution are different quantities. Indicative print time is material-dependent; no clinical outcome is inferred.
Tomographic printing
Tomolite illuminates a rotating material container from multiple angles to create a volumetric light-dose pattern. The finished construct is separated from uncured material after exposure.
Standard and performance configurations
Diameter and wavelength differ between configurations. Print time is indicative and material-dependent; the cylindrical vial geometry is not represented as a rectangular build box.
Explore the model family.
Introduction year has not been established from the reviewed source.
Explore Readily3D through the generationsRead this with the specifications
The product page documents cylindrical build diameters up to 6.3 mm for Standard and 12.5 mm for Performance, with height stated as at least 25 mm. This lower-bound height and vial geometry are not converted into a universal rectangular build volume.
A larger nominal envelope does not establish better print quality. Fit depends on the configuration, usable area, supports, and orientation.