SLAManufacturer image: 3DCeram3DCeram C101 EASY LAB
Laboratory-focused ceramic stereolithography system.
Source reviews: 2026-10-16.
Specifications are reported claims, not independent test results.
The details that matter.
Published specifications for this model. Follow a field's source for its configuration and measurement conditions; older fields refer to the profile's reference list.
| Introduction year | Not verified |
|---|---|
| Model family | C |
| Process | SLA |
| Build envelope (X × Y × Z) | 100 × 100 × 150 mm |
| Nominal box volume | 1.50 L · calculated from the envelope |
| Enclosure | Not verified |
| Materials cited in this profile | Ceramic-filled photopolymer resin |
| Manufacturer listing status | Manufacturer-listed |
| Regional stock and price | Check the manufacturer |
| Market grouping | Professional · editorial grouping |
Technical specifications
| Machine dimensions (mm) | 1095 × 1070 × 1980 Manufacturer L × depth × height; approximate. |
|---|---|
| Machine weight (kg) | 600 Approximate equipment weight. |
| Power Supply | 220–240 VAC, 50 Hz |
| Light Source | UV laser |
| Laser power (mW) | 300 |
| Laser Wavelength (nm) | 405 |
| Approximate Laser Spot (µm) | 60 |
| Z Axis Movement (mm) | 0.020–0.125 Published Z movement range, not declared finished-part accuracy. |
| Recommended Ambient Temperature (°C) | 20–25 |
| Maximum Ambient Change | 1 °C per hour |
| Relative Humidity | 50% |
| Compressed Air Requirement | 6 bar C1000 specifies dry air; C101 page appears to contain a typographical error after the pressure value. |
| Hybrid Option | Available |
| Minimum Starting Material (mL) | 60 |
| Optional Minimum Starting Material (mL) | 10 |
| Cartridge Volumes (mL) | 180, 360, 600, 920 |
Top-down ceramic printing
The laser cures ceramic-loaded layers from above while the build platform descends. Cartridge feed can be replenished during a print.
Research configuration
Open process parameters support material development in laboratories. The optional Small Amount of Material configuration reduces the starting feedstock requirement for experiments.
Explore the model family.
An exact introduction year has not been established in the reviewed sources.
Family: C · Current / announced
Explore 3DCeram through the generationsRead this with the specifications
The exact C101 EASY LAB product page verifies a 100 × 100 × 150 mm build envelope. The 10 mL starting-material figure requires the optional Small Amount of Material configuration; the standard minimum is 60 mL. No launch year is inferred.
A larger nominal envelope does not establish better print quality. Fit depends on the configuration, usable area, supports, and orientation.